Range: 30 Pa – 30 kPa
Accuracy: up to ±2.5% Full Scale
Compliance: CE, RoHS, ISO 9001
1. Product Overview
The A2 Series Differential Pressure Gauge is a low-pressure mechanical gauge designed for air and non-corrosive gases. It uses a magnet-helix movement to deliver stable, drift-free indication, especially suitable for very low differential pressure measurement.
2. Key Features
-
Magnet-helix indicating mechanism for low DP measurement
-
Wide range coverage: 0–30 Pa up to 0–30 kPa
-
High accuracy:
-
Standard: ±2% FS
-
Some low-range models: ±3% to ±4% FS
-
-
Inertia-free, drift-free pointer movement
-
Multiple unit options (Pa, inH₂O, mmH₂O, cmH₂O, kPa, psi)
-
Zero-center and dual-scale versions available
-
OEM / customized solutions supported
3. Indicating Mechanism (Working Principle)
-
Pressure is applied to both sides of a diaphragm.
-
Any pressure difference moves the diaphragm and linked spring.
-
A magnet attached to the spring rotates a magnetic helix.
-
The pointer fixed to the helix turns proportionally to the pressure difference.
-
No mechanical gear contact → high stability & long life
4. Applications
-
HVAC system monitoring
-
Filter condition and clogging detection
-
Fan and blower pressure measurement
-
Air velocity measurement
-
Orifice plate pressure drop
-
Cleanroom monitoring
-
Pharmaceutical & semiconductor manufacturing
-
General low-pressure air & gas measurement
5. Technical Specifications
Media
-
Air and non-combustible, compatible gases
Accuracy
-
±2% FS @ 21 °C (standard)
-
±3% FS on selected low ranges
-
±4% FS on ultra-low ranges (e.g. 0–0.25 inH₂O, 0–6 mmH₂O)
Ambient Temperature
-
–7 °C to +60 °C
Pressure Limits
-
Operating pressure limit: –68 to 100 kPa
-
Overpressure protection:
-
Relief plug opens at approx. 15 psig (100 kPa)
-
Process Connection
-
1/8″ female NPT
-
Duplicate high & low pressure ports
(one pair on side, one pair on back)
Mechanical
-
Case & bezel: Die-cast aluminum
-
Dial size: 4 inch (≈100 mm)
-
Mounting position: Vertical
-
Weight: ≈460 g
Standard Accessories
-
Two 1/8″ NPT plugs
-
Two 1/8″ pipe-to-rubber tubing adapters
-
Three flush-mounting adapters with screws


6. Measurement Ranges & Model Selection
A. Inch Water Column (inH₂O)
Standard Ranges
-
0–0.25 | 0–0.5 | 0–1 | 0–2 | 0–3 | 0–4 | 0–5 | 0–6
-
0–8 | 0–10 | 0–15 | 0–20 | 0–25 | 0–30 | 0–40 | 0–50 | 0–60 | 0–80 | 0–100 | 0–150
Zero-Center (±)
-
±0.25 | ±0.5 | ±1 | ±2 | ±5 | ±10 | ±15
B. Pascal (Pa)
-
0–30 | 0–60 | 0–100 | 0–125 | 0–250 | 0–300 | 0–500 | 0–750 Pa
Zero-Center Pa
-
±125 Pa | ±250 Pa | ±0.5 kPa | ±1.5 kPa
C. mmH₂O
-
0–6 | 0–10 | 0–25 | 0–50 | 0–80 | 0–100 mmH₂O
Zero-Center
-
±10 mmH₂O
D. cmH₂O
-
0–15 | 0–20 | 0–25 | 0–50 | 0–80 | 0–100 | 0–150 | 0–200 | 0–250 | 0–300 cmH₂O
Zero-Center
-
±2 | ±5 | ±15 cmH₂O
E. kPa
-
0–1 | 0–1.5 | 0–2 | 0–3 | 0–4 | 0–5 | 0–8 | 0–10
-
0–15 | 0–20 | 0–25 | 0–30 kPa
F. PSI
-
0–1 | 0–2 | 0–3 | 0–4 | 0–5 | 0–10 | 0–15 | 0–20 | 0–30 psi
G. Dual-Scale (English / Metric)
Examples:
-
0–0.5 inH₂O / 0–125 Pa
-
0–1 inH₂O / 0–250 Pa
-
0–2 inH₂O / 0–500 Pa
-
0–6 inH₂O / 0–1.5 kPa
-
0–10 inH₂O / 0–2.5 kPa
7. Compliance & Certification
-
CE
-
RoHS
-
ISO 9001:2000