Dimensions
-
2-29/32″ × 2-7/16″
-
73.81 mm × 61.93 mm
Key Features
-
Compact size with low cost and reliable accuracy
-
Glass-filled nylon housing with polycarbonate face cover
-
Suitable for rough and exposed environments
-
Built-in over-pressure protection
Specifications
Media
-
Air and compatible non-corrosive gases
Housing
-
Glass-filled nylon
-
Polycarbonate face cover
Accuracy
-
±5% of full scale at 70°F (21.1°C)
Rated Total Pressure
-
50 psig (3.455 bar) surge
-
30 psig (2.067 bar) continuous
-
Applies to either pressure connection
Ambient Temperature Range
-
20°F to 120°F
-
-6.7°C to 49°C
Mounting
-
Standard: Vertical
-
Other mounting positions: consult factory
Process Connections
-
Standard barbed fittings
-
For 3/16″ I.D. tubing
Weight
-
170.1 g (6 oz)
Order Information
DP Range – Inches of Water Column (in.w.c.)
| Model No. | Range |
|---|---|
| A5000-0 | 0 ~ 0.5 |
| A5001 | 0 ~ 1.0 |
| A5002 | 0 ~ 2.0 |
| A5003 | 0 ~ 3.0 |
| A5005 | 0 ~ 5.0 |
| A5010 | 0 ~ 10 |
| A5020 | 0 ~ 20 |
| A5040 | 0 ~ 40 |
| A5060 | 0 ~ 60 |
| A5100 | 0 ~ 100 |
DP Range – PSI
| Model No. | Range |
|---|---|
| A5205 | 0 ~ 5 |
| A5210 | 0 ~ 10 |
| A5215 | 0 ~ 15 |
| A5230 | 0 ~ 30 |
DP Range – mm Water Column (mm w.c.)
| Model No. | Range |
|---|---|
| A5000-25MM | 0 ~ 25 |
| A5000-50MM | 0 ~ 50 |
| A5000-100MM | 0 ~ 100 |
DP Range – Pascal (Pa)
| Model No. | Range |
|---|---|
| A5000-125Pa | 0 ~ 125 |
| A5000-250Pa | 0 ~ 250 |
| A5000-500Pa | 0 ~ 500 |
DP Range – Kilopascal (kPa)
| Model No. | Range |
|---|---|
| A5000-1KPa | 0 ~ 1 |
| A5000-3KPa | 0 ~ 3 |